CLEAN ROOM MONITORING – REGULATORY STANDARDS

CLEAN ROOM MONITORING – REGULATORY STANDARDS





Ø Air Classification as per Schedule M


Grade
Maximum permitted number of particles / m3 equal or above
at rest
in operation
0.5µm
5.0µm
0.5µm
5.0µm
A
3,520
29
3,500
29
B
35,200
293
3,52,000
2,930
C
3,52,000
2,930
35,20,000
29,300
D
35,20,000
29,300
not defined
not defined

Note:- 

  • Grade A and B correspond to with class  100, M 3.5, ISO 5  
  • Grade C correspond to with class 10000, M 5.5, ISO 7 
  • Grade D correspond to with class 100000, M 6.5, ISO 8

Ø  Air Classifications by US FDA guideline on Sterile Drug Products

Clean Area Classification
<0.5 µm Particles/ft3
<0.5 µm Particles/mt3
Microbiological Limit
cfu/ft3
cfu/m3
100
100
3,500
<1
<3
1000
1000
35,000
<2
<7
        10000
10000
350,000
<3
<18
      100000
100000
3,500,000
<25
<88



Ø  Air Classifications as per WHO 2002


Grade
Maximum Number Permitted / M3
Particles
Microorganisms
0.5µm
5.0µm
A (LAF)
3,500
0
<1
B
3,500
0
5
C
3,50,000
2,000
100
D
3,500,000
20,000
500

Note :-

  • Grade A and B correspond to with class 100, M 3.5, ISO 5 
  • Grade C correspond to with class 10000, M 5.5, ISO 7 
  • Grade D correspond to with class 100000, M 6.5, ISO 8

 Ø  Airborne Classification in the European union guide to Good Manufacturing Practice  


Grade
Maximum Permitted Number of Particles /m3 equal to or above
at rest
in operation
>= 0.5µm
>= 5.0µm
>= 0.5µm
>= 5.0µm
A
3500
0
3500
0
B
3500
0
350000
2000
C
350000
2000
3500000
20000
D
3500000
20000
not defined
not defined

Note :-
  • Grade A and B correspond to with class 100, M 3.5, ISO5 
  • Grade C correspond to with class 10000, M 5.5, ISO 7 
  • Grade D correspond to with class 100000, M 6.5, ISO 8

Ø  Clean room Environmental Monitoring

Sr. No.
Test
Frequency
1
Particle Monitoring in air
6 monthly
2
HEPA Filter Integrity Testing
6 monthly
3
Air Changes Rate Calculation
6 monthly
4
Air Pressure Differentials
Daily
5
Temperature and Humidity
Daily

6
Microbiological monitoring by settle plates and / or swabs in aseptic areas
Daily, and at decreased frequency in other
areas

Ø  Clean room Industry Design Thumb Rule

ISO
Class
Controls
Air Velocity at table
level in FPM
Air Changes Rate per Hour
HEPA
Coverage as
%
of Ceiling
1
Stringent
70 - 130
>750
100
2
Stringent
70 - 130
>750
100
3
Stringent
70 - 130
>750
100
4
Stringent
70 - 110
500 - 600
100
5
Stringent
70 – 90
150 - 400
100
6
Intermediate
25 – 40
60 – 100
33 – 40
7
Intermediate
10 – 15
25 – 40
10 – 15
8
Less Stringent
3 – 5
10 – 15
       
       05- 10          
Ø  Comparison between selected equivalent class of federal standards 209 and ISO 14644-1

  ISO 14644-1 classes   Class 3     Class 4       Class 5         Class 6         Class 7            Class 8
    Federal Standard       Class 1     Class 10     Class 100    Class 1000    Class 10000    Class 100000
                                                      
Ø  Comparison of international standards

Country and Standard
USA
209D
USA
209E
      Britain BS 5295
    Australia AS 1386
    France AFNOR NFX 44-101
Germany VDI 2083
ISO
Date of Current Issue
1988
1992
1989
1989
1981
1990
1999
1
M 1.5
C
            0.035
-
1
3
10
M 2.5
D
0.35
-
2
4
100
M 3.5
E or F
3.5
4000
3
5
1000
M 4.5
G or H
35
-
4
6
10000
M 5.5
J
350
400000
5
7
100000
M 6.5
k
            3500
4000000
6
8


Ø  EUG GMP 2002 Recommended Limits for Microbial Contamination


Grade
Air Sample cfu/m3
Settle Plates Dia 90 mm cfu/m3
contact Plates Dia 55 mm cfu/m3
Glove Print 5 fingers cfu/glove
A
<1
<1
<1
<1
B
10
5
5
5
C
100
50
25
-
D
200
100
50
-

Note :-
  • Grade A and B correspond to with class 100, M 3.5, ISO 5 
  • Grade C correspond to with class 10000, M 5.5, ISO 7 
  • Grade D correspond to with class 100000, M 6.5, ISO 8

Ø  Federal Standard 209D Class Limits

Class
Particles /ft3
Size
>= 0.1 µm
>= 0.2 µm
>= 0.3 µm
>= 0.5 µm
>= 5.0 µm
1
35
7.5
3
1
NA
10
350
75
30
10
NA
100
NA
750
300
100
NA
1000
NA
NA
NA
        1000
7
      10000
NA
NA
NA
      10000
70
    100000
NA
NA
NA
    100000
700

Ø  Federal Standard 209E Class Limits 


Class Name

>= 0.1µm


>= 0.2µm


>= 0.3µm


>= 0.5µm


>=5.0µm


Volume Units
M3
Ft3
M3
Ft3
M3
Ft3
M3
Ft3
M3
Ft3
SI
English










M 1

350
9.91
75.7
2.14
30.9
0.875
10.0
0.283
--
--
M 1.5
1
1240
35
265
7.50
106
3.00
35.3
1.00
--
--
M 2

3500
99.1
757
21.4
309
8.75
100
2.83
--
--
M 2.5 
10
12400
350
2650
75.0
1060
30.0
353
10.0
--
--
M 3

35000
991
7570
214
3090
87.5
1000
28.3
--
--
M 3.5 
100
--
--
26500
750
10600
300
3530
100
--
--
M 4

--
--
75700
2140
30900
875
10000
283
--
--
M 4.5
1000
--
--
--
--
--
--
35300
1000
247
7.00
M 5

--
--
--
--
--
--
100000
2830
618
17.5
M 5.5
10000
--
--
--
--
--
--
353000
10000
2470
70.0
M 6

--
--
--
--
--
--
1000000
28300
6180
175
M 6.5
100000
--
--
--
--
--
--
3350000
100000
24700
700
M 7

--
--
--
--
--
--
10000000
283000
61800
1750

Ø  ISO Standard 14644-1 Class Limits

ISO Classification Number
Maximum concentration limits( Particles/m3 of air) for particles equal to and larger than the considered sizes shown below
>= 0.1µm
>= 0.2µm
>= 0.3µm
>= 0.5µm
>= 1.0µm
>= 5.0µm
ISO Class 1
10
2




ISO Class 2
100
24
10
4


ISO Class 3
1000
237
102
35
8

ISO Class 4
10000
2370
1020
352
83

ISO Class 5
100000
23700
10200
3520
832
29
ISO Class 6
1000000
237000
102000
35200
8320
293
ISO Class 7



352000
83200
2930
ISO Class 8



3520000
832000
29300
   ISO Class 9



35200000
8320000
293000
                            
Ø  Particles in Outdoor Air



Number of Particles/m3 on Outdoor Air
Size in Microns
Dirty
Normal
Clean
>0.1
10000000000
3000000000
500000000
>0.3
300000000
90000000
20000000
>0.5
30000000
7000000
1000000


Ø Schedule of Mandatory Test to Demonstrate Continuing Compliance in Clean rooms

Test Parameter
Class
Maximum Time Interval
Particle Count Test
<= ISO 5
6 months
> ISO 5
12 months
Air Pressure Difference
All Classes
12 months
Airflow
All Classes
12 months

Ø Schedule of Optional  Test to Demonstrate Continuing Compliance in Clean rooms

Test Parameter
Class
Maximum Time Interval
Installed Filter Leakage
All Classes
24 months
Containment Leakage
All Classes
24 months
Recovery
All Classes
24 months
Airflow Visualization
All Classes
24 months


Ø  Special Requirements for ISO Class 3 Clean rooms

Special Requirements for ISO Class 3 Cleanrooms
Air Quality
Total Hydrocarbons <1 ppm; Na <0.1 µg/m3
Fresh Air Intake
0.5 m3 /min per sqm of cleanroom floor area
Vibration
<0.1 µ ( Building); <0.01 µ ( Equipment) rms
Noise
< 55 dbA
Temperature
.1 degree C
Humidity
< 2%
Magnetic field var
< 1 mG
Static charge
< 50 v


Ø  Types of Operations for Aseptic Preparations
                          Grade             Types of Operations for Aseptic Preparations
A                                      Aseptic preparation and filling
B                                      Background room conditions for activities requiring Grade A
C                                      Preparation of Solution to be filtered
D                                      Handling of components after washing

Note :-
  • Grade A and B correspond to with class 100, M 3.5, ISO 5  
  • Grade C correspond to with class 10000, M 5.5, ISO 7 
  • Grade D correspond to with class 100000, M 6.5, ISO 8

Comments

Popular posts from this blog

DATA INTEGRITY (ALCOA ++)

 INTRODUCTION   The purpose of this guidance is to clarify the role of data integrity in current good manufacturing  practice (CGMP) for drugs, as required in 21 CFR parts 210, 211, and 212. Part 210 covers  Current Good Manufacturing Practice in Manufacturing, Processing, Packing, or Holding of  Drugs; General; part 211 covers Current Good Manufacturing Practice for Finished  Pharmaceuticals; and part 212 covers Current Good Manufacturing Practice for Positron  Emission Tomography Drugs. This guidance provides the Agency’s current thinking on the creation and handling of data in accordance with CGMP requirements. FDA expects that data be reliable and accurate (see the “Background” section). CGMP  regulations and guidance allow for flexible and risk-based strategies to prevent and detect data  integrity issues. Firms should implement meaningful and effective strategies to manage their data  integrity risks based upon their process understanding and knowledge management of tec

PERMITTED DAILY EXPOSURE (PDE)

PERMITTED DAILY EXPOSURE (PDE) or ACCEPTANCE DAILY EXPOSURE Introduction During the manufacture of medicinal products accidental cross contamination can result from the uncontrolled release of dust, gases, vapours, aerosols, genetic material or organisms from active substances, other starting materials, and other products being processed concurrently, as well as from residues on equipment, and from operators ’ clothing. Due to the perceived risk, certain classes of medicinal product have previously been required to be manufactured in dedicated or segregated self contained facilities including, “certain antibiotics, certain hormones, certain cytotoxics and certain highly active drugs”. Until now no official guidance is available in order to assist manufacturers to differentiate between individual products within these specified classes. METHODS FOR ESTABLISHING EXPOSURE LIMITS The Gaylor-Kodell method of risk assessment (Gaylor, D. W. and Kodell, R. L.: Linea

21 Code of Federal Regulations Parts 211 Subpart K-Returned and Salvaged Drug Products

21 Code of Federal Regulations Parts 211 Subpart K-Returned and Salvaged Drug Products § 211.204 Returned drug products. Returned drug products shall be identified as such and held. If the conditions under which returned drug products have been held, stored, or shipped before or during their return, or if the condition of the drug product, its container, carton, or labeling, as a result of storage or shipping, casts doubt on the safety, identity, strength, quality or purity of the drug product, the returned drug product shall be destroyed unless examination, testing, or other investigations prove the drug product meets appropriate standards of safety, identity, strength, quality, or purity. A drug product may be reprocessed provided the subsequent drug product meets appropriate standards, specifications, and characteristics. Records of returned drug products shall be maintained and shall include the name and label potency of the drug product dosage form, lot number (or co